SUPPORT / SAMPLES & SAS NOTES
 

Support

Usage Note 20351: Support added for SPD Server START/ENDOBS LIBNAME options with values larger than 2G

DetailsHotfixAboutRate It

Prior to SPD Server 4.4 TSM2, STARTOBS/ENDOBS values larger than 2G caused values to resolve to negative numbers.

This caused problems with parallel joins because STARTOBS/ENDOBS values are used to bracket sections of the table to join in parallel. Negative values cause the join to fail.

Select the Hot Fix tab in this note to access the hot fix for this issue.



Operating System and Release Information

Product FamilyProductSystemProduct ReleaseSAS Release
ReportedFixed*ReportedFixed*
SPDSScalable Performance Data ServerMicrosoft Windows NT Workstation4.49.1 TS1M3
Solaris4.49.1 TS1M3
Solaris for x644.49.1 TS1M3
64-bit Enabled Solaris4.49.1 TS1M3
Linux on Itanium4.49.1 TS1M3
HP-UX4.49.1 TS1M3
HP-UX IPF4.49.1 TS1M3
64-bit Enabled AIX4.49.1 TS1M3
64-bit Enabled HP-UX4.49.1 TS1M3
AIX4.49.1 TS1M3
* For software releases that are not yet generally available, the Fixed Release is the software release in which the problem is planned to be fixed.