Problem Note 19990: A floating-point exception error can occur when you use SAS® Data Integration Studio 3.4 to update table metadata in the SAS/ACCESS® Interface to ODBC

DetailsHotfixAboutRate It

The following error can occur when you use SAS Data Integration Studio 3.4 to update table metadata in the SAS/ACCESS® Interface to ODBC:

ERROR: Invalid Operation.
ERROR: Termination due to floating point exception 

This error is issued after Hot Fix E9OD02 has been applied to SAS/ACCESS Interface to ODBC.

Outside of the metadata, this issue surfaces as a return of incorrect data. For example, in one test, two rows are returned (one row has a missing value for INDEXNAME, which is incorrect).

Select the Hot Fix tab in this note to access the hot fix for this issue.

Apply the hot fix to resolve this problem and to avoid crashes or invalid data when you run queries directly or via operations that involve the METALIB procedure.

Attention:This hot fix is intended for UNIX and Windows customers running the DB2 Client 8.1 Fix Pack 9 or later. Customers running earlier versions of the DB2 Client should only install hot fixes prior to E9D205.



Operating System and Release Information

Product FamilyProductSystemSAS Release
ReportedFixed*
SAS SystemSAS/ACCESS Interface to ODBC64-bit Enabled HP-UX9.1 TS1M39.2 TS1M0
64-bit Enabled Solaris9.1 TS1M39.2 TS1M0
Linux9.1 TS1M39.2 TS1M0
64-bit Enabled AIX9.1 TS1M39.2 TS1M0
* For software releases that are not yet generally available, the Fixed Release is the software release in which the problem is planned to be fixed.