Problem Note 19989: A floating-point exception error can occur when you use SAS® Data Integration Studio 3.4 to update table metadata in the SAS/ACCESS® Interface to DB2
The following error message can occur when you use SAS Data Integration
Studio 3.4 to update table metadata in the SAS/ACCESS Interface to DB2:
ERROR: Invalid Operation.
ERROR: Floating Point Exception
 This error is issued after Hot Fix E9D203 has been applied to SAS/ACCESS Interface to DB2.
Outside of the metadata, this issue surfaces as a return of incorrect data.  For example, in one test, two rows are returned (one has a missing value for  INDEXNAME, which is incorrect).
Select the Hot Fix tab in this note to access the hot fix for this issue.
ATTENTION: This Hot Fix is intended for Unix and Windows customers running the DB2 Client 8.1 Fix Pack 9 or later. Customers running earlier versions of the DB2 Client should only install hot fixes prior to E9D205.
Operating System and Release Information
| SAS System | SAS/ACCESS Interface to DB2 | 64-bit Enabled HP-UX | 9.1 TS1M3 SP3 | 9.2 TS1M0 | 
| 64-bit Enabled Solaris | 9.1 TS1M3 SP3 | 9.2 TS1M0 | 
| Linux | 9.1 TS1M3 SP3 | 9.2 TS1M0 | 
| 64-bit Enabled AIX | 9.1 TS1M3 SP3 | 9.2 TS1M0 | 
*
        For software releases that are not yet generally available, the Fixed
        Release is the software release in which the problem is planned to be
        fixed.
       
| Type: | Problem Note | 
| Priority: | high | 
| Topic: | SAS Reference  ==>  LIBNAME Engines Data Management  ==>  Data Sources  ==>  External Databases  ==>  DB2
 
 | 
| Date Modified: | 2009-07-10 16:30:44 | 
| Date Created: | 2007-04-17 15:19:46 |