Problem Note 19989: A floating-point exception error can occur when you use SAS® Data Integration Studio 3.4 to update table metadata in the SAS/ACCESS® Interface to DB2
The following error message can occur when you use SAS Data Integration
Studio 3.4 to update table metadata in the SAS/ACCESS Interface to DB2:
ERROR: Invalid Operation.
ERROR: Floating Point Exception
This error is issued after Hot Fix E9D203 has been applied to SAS/ACCESS Interface to DB2.
Outside of the metadata, this issue surfaces as a return of incorrect data. For example, in one test, two rows are returned (one has a missing value for INDEXNAME, which is incorrect).
Select the Hot Fix tab in this note to access the hot fix for this issue.
ATTENTION: This Hot Fix is intended for Unix and Windows customers running the DB2 Client 8.1 Fix Pack 9 or later. Customers running earlier versions of the DB2 Client should only install hot fixes prior to E9D205.
Operating System and Release Information
SAS System | SAS/ACCESS Interface to DB2 | 64-bit Enabled HP-UX | 9.1 TS1M3 SP3 | 9.2 TS1M0 |
64-bit Enabled Solaris | 9.1 TS1M3 SP3 | 9.2 TS1M0 |
Linux | 9.1 TS1M3 SP3 | 9.2 TS1M0 |
64-bit Enabled AIX | 9.1 TS1M3 SP3 | 9.2 TS1M0 |
*
For software releases that are not yet generally available, the Fixed
Release is the software release in which the problem is planned to be
fixed.
Type: | Problem Note |
Priority: | high |
Topic: | SAS Reference ==> LIBNAME Engines Data Management ==> Data Sources ==> External Databases ==> DB2
|
Date Modified: | 2009-07-10 16:30:44 |
Date Created: | 2007-04-17 15:19:46 |