SUPPORT / SAMPLES & SAS NOTES
 

Support

Problem Note 18911: "ERROR: System Exiting Status=401" message occurs when multiple processes update a SPD Engine data set

DetailsHotfixAboutRate It

When multiple processes attempt to update the same SPDE data set, locking errors occur as SPDE only supports member-level locking. When SPDE attempts to produce an appropriate diagnostic message at SAS® 9.1.3 SP4, error messages such as one or more of the following may occur in the log:

   Conversation termination; status=1

   System Exiting Status=401

   tkthread: Access violation

The last message only occurs if the system option

debug="spde: hs_threads"

has been specified when SAS is initialized.

Note: the fix associated with this SAS Note only allows a more appropriate diagnostic message to be generated for the locking issue. It does not change the fact that SPDE requires exclusive access of the SPDE data set in order to update it.

Select the Hot Fix tab in this note to access the hot fix for this issue.



Operating System and Release Information

Product FamilyProductSystemSAS Release
ReportedFixed*
SAS SystemBase SASSolaris for x649.1 TS1M3 SP49.2 TS1M0
* For software releases that are not yet generally available, the Fixed Release is the software release in which the problem is planned to be fixed.