Problem Note 17395: BMC MAINVIEW Batch Optimizer & Data Accelerator Compression Software
receive S0C4 ABEND
BMC's MAINVIEW Batch Optimizer and Data Accelerator Compression have
a component named Job Optimizer Pipes. This component receives an 0C4
in module JOPSEPH on a CLI that uses register 15 as the base. In the
job output below, OFIXED is the file that is now a pipe.
DUMP TITLE=BMC282333E PIPE HANDLER ABEND: S0C4 AT 2515910E (JOPSEPH
+X'00B606') J=LR4050P1 DD=OFIXED A=OPEN
BMC282333E PIPE HANDLER ABEND: S0C4 AT 2515910E (JOPSEPH +X'00B606')
J=LR4050P1 DD=OFIXED A=OPEN
BMC282323W OFIXED - JOB IN ERROR DUE TO PIPHNDLABND IN STEP SAS
We saw a similar problem with Computer Associates Unicenter Log
Compressor for DB2. See #14768 for further details of this problem.
The fix is in Service Pack 3 and above.
Select the Hot Fix tab in this note to access the hot fix for this issue.
Operating System and Release Information
SAS System | Base SAS | z/OS | 9.1 TS1M2 | 9.2 TS1M0 |
*
For software releases that are not yet generally available, the Fixed
Release is the software release in which the problem is planned to be
fixed.
Type: | Problem Note |
Priority: | |
Topic: | Data Management ==> Access ==> External I/O
|
Date Modified: | 2006-06-14 10:52:04 |
Date Created: | 2006-04-03 11:30:57 |