Problem Note 16476: System abend 0C4 in module SASTK
There is an intermittent problem where jobs abend with a S0C4 in module
SASTK. The job may timeout with a system 522 abend after the 0C4. If there are
subsequent conditional execution steps in the JCL that don't run as a
result, the job will need to be resubmitted. See example message below.
IEA995I SYMPTOM DUMP OUTPUT 053
SYSTEM COMPLETION CODE=0C4 REASON CODE=00000011
TIME=18.27.38 SEQ=05867 CPU=0000 ASID=0347
PSW AT TIME OF ERROR 078D2000 8E723F0A ILC 4 INTC 11
ACTIVE LOAD MODULE ADDRESS=0E7063A8
OFFSET=0001DB62
This problem is corrected in SAS 9.2.
Select the Hot Fix tab in this note to access the hot fix for this issue.
Operating System and Release Information
| SAS System | Base SAS | z/OS | 9.1 TS1M3 | 9.2 TS1M0 |
*
For software releases that are not yet generally available, the Fixed
Release is the software release in which the problem is planned to be
fixed.
| Type: | Problem Note |
| Priority: | high |
| Date Modified: | 2006-09-08 11:21:17 |
| Date Created: | 2005-11-11 11:39:19 |