Problem Note 15266: Some function keys may be blank when editing PROGRAM or SCL entries on
the mainframe
Some function keys may be blank in the BUILD.KEYS entry while you are
editing SAS/AF PROGRAM and SCL entries within SAS 9 on the mainframe.
To circumvent this problem, save your own copy of BUILD.KEYS in your
SASUSER.PROFILE catalog. To do this, edit a PROGRAM or SCL entry and
issue the KEYS command to be taken to the Keys window. Type the values
of commands that you would like to execute from each function key. Issue
the END command to save your settings and close the Keys window. Your
changes are now saved in the BUILD.KEYS entry in the SASUSER.PROFILE
catalog and these values will be used instead of the default values.
Select the Hot Fix tab in this note to access the hot fix for this issue.
Operating System and Release Information
SAS System | SAS/AF | z/OS | 9 TS M0 | 9.1 TS1M3 SP3 |
*
For software releases that are not yet generally available, the Fixed
Release is the software release in which the problem is planned to be
fixed.
Type: | Problem Note |
Priority: | high |
Date Modified: | 2005-10-21 14:39:42 |
Date Created: | 2005-05-20 14:05:24 |