Problem Note 11899: SAS® Data Quality Server does not execute on Windows Itanium machines
When attempting to perform a load of any locale from any Quality
Knowledge Base on Microsoft Windows for 64-Bit Itanium machines, the following error
occurs:
Fault Code = 80000002
ERROR: Unknown Program fault In Task [ Submit )
Exception occurred at (46E9A8F0)
Task Traceback
Address Frame (DBGHELP API Version 4.0 rev 5)
0000000046E9A8F0 000006FBF10E0C28 0001:00000000000E88F0 saszdq.dll
0000000046E99B80 000006FBF10E0C10 0001:00000000000E7B80 saszdq.dll
0000000046E97610 000006FBF10E0BB8 0001:00000000000E5610 saszdq.dll
0000000046EA3D10 000006FBF10E0AA0 0001:00000000000F1D10 saszdq.dll
0000000046EA2D00 000006FBF10E0A70 0001:00000000000F0D00 saszdq.dll
0000000046EA2160 000006FBF10E0A20 0001:00000000000F0160 saszdq.dll
0000000046EA2080 000006FBF10E09D0 0001:00000000000F0080 saszdq.dll
0000000046E92600 000006FBF10E0938 0001:00000000000E0600 saszdq.dll
0000000046DF4BD0 000006FBF10E0890 0001:0000000000042BD0 saszdq.dll
0000000046DF2DE0 000006FBF10E0860 0001:0000000000040DE0 saszdq.dll
0000000046EE1530 000006FBF10E0830 0001:000000000012F530 saszdq.dll
0000000046FB5060 000006FBF10E06C0 0001:0000000000003060 sasdqfam.dll
0000000046FB3AF0 000006FBF10E0678 0001:0000000000001AF0 sasdqfam.dll
0000000046FB2A80 000006FBF10E0618 0001:0000000000000A80 sasdqfam.dll
00000000672E33A0 000006FBF10E05A0 0001:00000000000A13A0 sasxkern.dll
0000000066F633E0 000006FBF10E0498 0001:00000000000413E0 sasxshel.dll
0000000066F258F0 000006FBF10E03D8 0001:00000000000038F0 sasxshel.dll
0000000066F67BC0 000006FBF10E0258 0001:0000000000045BC0 sasxshel.dll
0000000066FC41C0 000006FBF10E01A8 0001:00000000000A21C0 sasxshel.dll
0000000066FC2DD0 000006FBF10E00F0 0001:00000000000A0DD0 sasxshel.dll
0000000066FCDDC0 000006FBF10E00B0 0001:00000000000ABDC0 sasxshel.dll
0000000067BF27C0 000006FBF10E0090 0001:00000000000307C0 sashost.dll
0000000067BFE510 000006FBF10E0040 0001:000000000003C510 sashost.dll
0000000077D24400 000006FBF10E0000 kernel32:GetDateFormatW+0x70070
ERROR: Generic critical error.
|
This error is caused by the manner in which Windows for 64-Bit Itanium interprets a specific function within the SAS Data Quality Server code. The only way to resolve this issue is to apply the hot fix.
Select the Hot Fix tab in this note to access the hot fix for this issue.
Operating System and Release Information
SAS System | SAS Data Quality Server | Microsoft® Windows® for 64-Bit Itanium-based Systems | 9.1 TS1M2 | 9.1 TS1M3 SP2 |
*
For software releases that are not yet generally available, the Fixed
Release is the software release in which the problem is planned to be
fixed.
Type: | Problem Note |
Priority: | alert |
Date Modified: | 2013-06-19 10:46:10 |
Date Created: | 2004-03-03 13:24:26 |