Problem Note 11399: Duplicate Checking logic only searches the first SOURCLIB dataset for
$$DUPxx members
If more than one USER.SOURCLIB is specified for CMPROCES and the
$$DUPxxx for the collector used is not first, when INPUT FILTERING is
ACTIVE the %CMPROCES or %CPPROCES will fail with the following ERROR:
ERROR: File user.test.sourclib($$DUPxxx) has not been defined.
WARNING: Physical file does not exist, user.test.sourclib($DUPxxx)
even if a subsequent USER.SOURCLIB library has the entry defined.
A Technical Support hot fix for SAS IT Resource Management Release 2.6
for this issue is available at:
http://www.sas.com/techsup/download/hotfix/itrm26.html
Operating System and Release Information
| SAS System | SAS IT Management Solutions Core Components MVA Data | z/OS | 2.5 | 2.7 | | |
*
For software releases that are not yet generally available, the Fixed
Release is the software release in which the problem is planned to be
fixed.
| Type: | Problem Note |
| Priority: | medium |
| Topic: | System Administration ==> Servers
|
| Date Modified: | 2004-02-23 14:54:40 |
| Date Created: | 2003-12-02 11:36:10 |