Note: See Combined Shewhart-Cusum Scheme in the SAS/QC Sample Library.
Lucas and Crosier (1982) introduced a combined Shewhart-cusum scheme that is illustrated in this example. Also refer to Ryan (1989). The data set used here is Cans
, which is created in Creating a One-Sided Cusum Chart with a Decision Interval.
The first step is to compute and save one-sided cusums to detect a positive shift from the mean.
proc cusum data=Cans; xchart Weight*Hour / nochart mu0 = 8.100 /* target mean for process */ sigma0 = 0.050 /* known standard deviation */ delta = 1 /* shift to be detected */ h = 3 /* cusum parameter h */ k = 0.5 /* cusum parameter k */ scheme = onesided outtable = Tabcus ( drop = _var_ _subn_ _exlim_ rename = ( _cusum_ = _subr_ _h_ = _uclr_ ) ) ; run;
Note that a headstart value is not used here but can be specified with the HSTART= option. Several variables in the OUTTABLE= data set are dropped or renamed so that they can later be read by the SHEWHART procedure.
The next step is to construct a Shewhart chart (not shown) for individual measurements.
proc shewhart data=Cans; irchart Weight*Hour / nochart mu0 = 8.100 sigma0 = 0.050 outtable = Tabx ( drop = _subr_ _lclr_ _r_ _uclr_ ); id comment; run;
By default, limits are computed, but the multiple of can be modified with the SIGMAS= option. As before, the results are saved in an OUTTABLE= data set.
Next, the two OUTTABLE= data sets are merged.
data Combine; merge Tabx Tabcus; by Hour; _lclr_ = 0.0; _r_ = 0.5 * _uclr_; run;
The data set Combine
has the structure required for a TABLE= data set used with the IRCHART statement in the SHEWHART procedure (see the section
TABLE= Data Set).
Finally, the combined scheme is displayed with the SHEWHART procedure.
ods graphics on; title "Combined Shewhart-Cusum Analysis for Weight"; proc shewhart table=Combine; irchart Weight*Hour / odstitle = title ypct1 = 50 noctl2 markers ucllabel2 = 'h=0.3' outlabel = ( comment ) outlabel2 = ( comment ) split = '/'; label _subi_ = 'Shewhart/Cusum'; run;
The chart is shown in Output 6.3.1.
Note that a shift is detected by the cusum scheme but not by the Shewhart chart. The point exceeding the decision interval
is labeled with the variable comment
created in the data set Cans
.
Lucas and Crosier (1982) tabulates average run lengths for combined Shewhart-cusum schemes. The scheme used here has an ARL of 111.1 for and an ARL of 6.322 for .