requests probability limits. If you specify ALPHA=, the control limits are computed so that the probability is that a single moving average exceeds its control limits. The value of can range between 0 and 1. This assumes that the process is in statistical control and that the data follow a normal distribution. For the equations used to compute probability limits, see Control Limits.
Note the following:
As an alternative to specifying ALPHA=, you can read from the variable _ALPHA_
in a LIMITS= data set by specifying the READALPHA option.
As an alternative to specifying ALPHA= (or reading _ALPHA_
from a LIMITS= data set), you can request “ control limits” by specifying SIGMAS=k (or reading _SIGMAS_
from a LIMITS= data set).
If you specify neither the ALPHA= option nor the SIGMAS= option, the procedure computes control limits by default.
requests constant upper and lower control limits for all subgroups having the following values:
Here w is the span of the moving average, and n is the nominal sample size associated with the control limits. Substitute for k if you specify probability limits with the ALPHA= option. When you do not specify the ASYMPTOTIC option, the control limits are computed using the exact formulas in Table 9.9. Use the ASYMPTOTIC option only if all the subgroup sample sizes are the same or if you specify LIMITN=n.
specifies the color used for the symbol requested with the MEANSYMBOL= option in traditional graphics. This option is ignored unless you are producing traditional graphics.
specifies either a fixed or varying nominal sample size for the control limits.
If you specify LIMITN=n, moving averages are calculated and displayed only for those subgroups with a sample size equal to n, unless you also specify the ALLN option, which causes all the moving averages to be calculated and displayed. By default (or if you specify LIMITN=VARYING), moving averages are calculated and displayed for all subgroups, regardless of sample size.
specifies a character used in legacy line printer charts to plot the subgroup mean for each subgroup. By default, subgroup means are not plotted. This option is ignored unless you specify the LINEPRINTER option in the PROC MACONTROL statement.
specifies a symbol used to plot the subgroup mean for each subgroup in traditional graphics. By default, subgroup means are not plotted. This option is ignored unless you are producing traditional graphics.
specifies a known (standard) value for the process mean . By default, is estimated from the data.
Note: As an alternative to specifying MU0=, you can read a predetermined value for from the variable _MEAN_
in a LIMITS= data set.
See Example 9.6.
specifies that control limit parameters for each process listed in the MACHART statement are not to be read from the LIMITS= data set specified in the PROC MACONTROL statement.
The following example illustrates the NOREADLIMITS option:
proc macontrol data=Pistons limits=Diamlim; machart Diameter*Hour; machart Diameter*Hour / noreadlimits span=3; run;
The first MACHART statement reads the control limits from the first observation in the data set Diamlim
for which the variable _VAR_
is equal to 'Diameter' and the variable _SUBGRP_
is equal to 'Hour'. The second MACHART statement computes estimates of the process mean and standard deviation for the control
limits from the measurements in the data set Pistons
. Note that the second MACHART statement is equivalent to the following statements, which would be more commonly used:
proc macontrol data=Pistons; machart Diameter*Hour / span=3; run;
For more information about reading control limit parameters from a LIMITS= data set, see the READLIMITS option later in this list.
specifies that the variable _ALPHA_
, rather than the variable _SIGMAS_
, is to be read from a LIMITS= data set when both variables are available in the data set. Thus the limits displayed are probability
limits. If you do not specify the READALPHA option, then _SIGMAS_
is read by default.
reads control limit parameters from a LIMITS= data set (specified in the PROC MACONTROL statement) for each process listed in the MACHART statement. The control limit parameters for a particular process are read from the first observation in the LIMITS= data set for which
the value of _VAR_
matches process
the value of _SUBGRP_
matches the subgroup-variable
the value of _INDEX_
matches value
The value can be up to 48 characters and must be enclosed in quotes.
specifies that control limit parameters are to be read from a LIMITS= data set specified in the PROC MACONTROL statement. The parameters for a particular process are read from the first observation in the LIMITS= data set for which
the value of _VAR_
matches process
the value of _SUBGRP_
matches the subgroup variable
Note: In SAS 6.10 and later releases, the READLIMITS option is not necessary.
specifies a known (standard) value for the process standard deviation . The value must be positive. By default, the MACONTROL procedure estimates from the data using the formulas given in Methods for Estimating the Standard Deviation.
Note: As an alternative to specifying SIGMA0=, you can read a predetermined value for from the variable _STDDEV_
in a LIMITS= data set.
specifies the width of the control limits in terms of the multiple k of the standard error of the plotted moving averages on the chart. The value of k must be positive. By default, k = 3 and the control limits are limits.
specifies the number of terms used to calculate the moving average (value is an integer greater than 1). The SPAN= option is required unless you read control limit parameters from a LIMITS= data set or a TABLE= data set. See Plotted Points and Choosing the Span of the Moving Average for details.