Installation qualification
and operational qualification is implemented with and illustrated
by the use of the validate_iqoq sample driver, located in the
sample study library directory/cst-framework-1.5/programs folder.
This is a two-step process.
-
Select the CST-FRAMEWORK
standard, and run the checks that are defined in the validation_control_glmeta
view of the internal validation validation_master data set.
This is a set of 64
checks (checkid < CSTV100) that look only at the global standards
library metadata folder.
-
Select 1 to
n specific
standards, and run the checks that are defined in the validation_control_stdiqoq
view of the internal validation validation_master data set.
This is a set of 30
checks (checkid > CSTV100 that are relevant to installation qualification
and operational qualification issues) that look only at the metadata
libraries other than the global standards library metadata folder.
Note: The validation Results data
set that is generated by the internal validation installation qualification
and operational qualification contains many observations. Your number
of observations can differ from the numbers shown in this document
due to installation configurations that differ from a default installation
of the SAS Clinical Standards Toolkit. For example, CDSIC SEND might
not be installed.