V6-EIS-E179
Program halt from custom computed values when division by zero occurs
|
If you select Computed Values while executing an object such as a 3D
Business Graphs in SAS/EIS Software and define a custom computation thatresults in a divisor of 0, then you will receive a program halt upon
selecting OK to exit the window.
For example, the computation may be
value001/value002
A possible circumvention would be the following:
value001/max(value002,0.00000000000000001)
| Products: | EIS |
| Component: | EIS |
| Priority: | MED |
| Status: | Outstanding Problem |
| Date: | Tue, 30 Sep 1997 |
| System | Release Reported | Release Fixed |
| AIX/6000 | 6.12 TS020 | 6.12 TS045 |
| HP-UX Operating Systems | 6.12 TS020 | 6.12 TS045 |
| IBM OS/2 | 6.12 TS020 | 6.12 TS045 |
| Solaris | 6.12 TS020 | 6.12 TS045 |
| OpenVMS Alpha | 6.12 TS020 | 6.12 TS045 |
| Windows 3.11 | 6.12 TS020 | 6.12 TS045 |
| Windows NT | 6.12 TS020 | 6.12 TS045 |
| Windows 95 | 6.12 TS020 | 6.12 TS045 |
| Compaq Tru64 Unix | 6.12 TS040 | |
| Macintosh | 6.12 TS040 |
No Fixes Available