Problem Note 1658: Methods executed from DFINIT on a Data Table object may result in a
program halt
If you execute a method such as _setHeldColumns on a Data Table object
in a SAS/AF FRAME entry from the DFINIT labeled section of the model's
SCL entry and that method requires updates from the model, you may
experience a program halt when DFINIT executes. Depending on the
method, you may receive an error message such as
ERROR: Out of range value detected.
To circumvent the problem, execute the method from the INIT label of the
FRAME's SCL entry.
Operating System and Release Information
| Product Family | Product | System | Reported Release | Fixed Release* |
| SAS System | SAS/AF | Solaris | 8 TS M0 | 8.1 TS1M0 |
| Microsoft Windows 95/98 | 8 TS M0 | 8.1 TS1M0 |
| Microsoft Windows NT Workstation | 8 TS M0 | 8.1 TS1M0 |
| 64-bit Enabled Solaris | 8 TS M0 | 8.1 TS1M0 |
| OS/2 | 8 TS M0 | 8.1 TS1M0 |
| IRIX | 8 TS M0 | 8.1 TS1M0 |
| HP-UX | 8 TS M0 | 8.1 TS1M0 |
| ABI+ for Intel Architecture | 8 TS M0 | 8.1 TS1M0 |
| 64-bit Enabled AIX | 8 TS M0 | 8.1 TS1M0 |
| 64-bit Enabled HP-UX | 8 TS M0 | 8.1 TS1M0 |
| OpenVMS Alpha | 8 TS M0 | 8.1 TS1M0 |
| Tru64 UNIX | 8 TS M0 | 8.1 TS1M0 |
| AIX | 8 TS M0 | 8.1 TS1M0 |
*
For software releases that are not yet generally available, the Fixed
Release is the software release in which the problem is planned to be
fixed.
| Type: | Problem Note |
| Priority: | medium |
| Date Modified: | 2000-07-03 16:35:32 |
| Date Created: | 2000-02-07 10:52:45 |