| All Exercises |
Problem |
Sample Data |
Solution |
 |
|
|
Select an Exercise for |
Click any exercise title to see the problem for that exercise. Then you can view and download sample data, complete the exercise, and check the solution.
Wired 3 Determine whether electrical measurements taken outside and inside a chamber differ.
|
College Course Test Scores 3: Problem |
An instructor at a community college is interested in examining a set of score changes between a pair of tests given in one of his college courses. He issued a pretest on the first day of class, and after a few weeks of lecture he issued a posttest on the same material. The instructor recorded the scores on both tests, as well as the difference in scores (posttest-pretest) for each student.
Carry out the sign test to Determine whether there is evidence that the scores on the posttest were different than those on the pretest for the students. |
 SAS Institute Inc.
Printer Friendly |
College Course Test Scores 3: Sample Data | |
The Score data set contains data about pretest and postest scores for students in a college course. These are the variables in the data set: Name | Type | Description | | Student | char | student | | PreTest | num | pretest score | | PostTest | num | posttest score | | ScoreChange | num | difference between posttest score and pretest score | |
|
Source of Data
|
This data is sample data from SAS Institute Inc. |
College Course Test Scores 3: Solution |
The value of the sign test statistic is M = -1, with a p-value of 0.7744. This gives insufficient evidence of a significant difference between pretest and posttest scores for the students. |
Wired 3: Problem |
An experiment was conducted in which electrical measurements were taken on 24 wiring boards. Each board was measured first when soldering was completed, and again after three weeks in a chamber with a controlled environment of high temperature and humidity.
The Shapiro-Wilk W test for Normality for the data yielded a p-value of 0.0076, indicating that the data are significantly non-Normal. Use the Wilcoxon signed-rank test to determine if there is a significant difference (at level α = 0.05) between the outside and inside chamber measurements.~nl~ |
 Lee Creighton (modified by Paris Faison) SAS Institute Inc.
Printer Friendly |
Wired 3: Sample Data | |
The Chamber data set represents electrical measurements on 24 wiring boards. Measurements were taken both outside and inside a chamber, and the difference between these measurements (outside – inside) was also recorded. These are the variables in the data set: Name | Type | Description | | board | num | identifier for wiring board | | outside | num | electrical measurement taken outside the chamber | | inside | num | electrical measurement taken inside the chamber | | diff | num | the difference between the measurements (outside – inside) | |
|
Source of Data
|
Sall, J., Creighton, L., & Lehman, A. (2006). JMP Start Statistics, Third Edition. Cary, NC: SAS Institute Inc. |
Wired 3: Solution |
The two dependent samples for this analysis were the paired outside and inside chamber measurements taken for each board. From the UNIVARIATE procedure in SAS, the Wilcoxon signed-rank test gives a p-value of 0.0106, which gives evidence of a significant difference between the outside and inside chamber measurements. |
|