Problem Note 61408: Task switch before recalculating results in an Internet Explorer crash
In SAS® Merchandise Planning, switching tasks without recalculating the worksheet might cause Internet Explorer to stop responding. If you edit a KPI and then attempt to switch tasks, you are presented with following options:
- Select YES to recalculate the worksheet.
- Select NO to return to the current task.
If you select YES, then the worksheet should recalculate the current task and then switch to the selected task. However, if the KPI that was edited has an aggregation rule of calc/calc/calc or calcplug/calcplug/calcplug, then selecting YES before the task switch causes Internet Explorer to stop responding. You then have to close the browser so that the worksheet resets.
As a workaround, if prompted, select NO to return to the current task and manually recalculate the task before switching to a new task.
Operating System and Release Information
SAS System | SAS Merchandise Financial Planning | Microsoft Windows Server 2012 R2 Std | 6.7 | 6.8 | 9.4 TS1M4 | 9.4 TS1M5 |
64-bit Enabled AIX | 6.7 | 6.8 | 9.4 TS1M4 | 9.4 TS1M5 |
Linux for x64 | 6.7 | 6.8 | 9.4 TS1M4 | 9.4 TS1M5 |
*
For software releases that are not yet generally available, the Fixed
Release is the software release in which the problem is planned to be
fixed.