Problem Note 6913: WARNING: Apparent symbolic reference SLIST not resolved
Customers running IT Charge Manager 2.3 may experience the following
error:
1 ecsusp.&slist
+ _
+ 22
_____
+ 202
WARNING: Apparent symbolic reference SLIST not resolved.
ERROR 22-322: Expecting a name.
+ERROR 22-322: Expecting a name.
+ERROR 22-322: Expecting a name.
The macro variable slist in macro ES_X230 was not being initialized so
that if the call symput statement is not executed, the macro variable
&slist cannot be resolved correctly.
To correct this problem, apply the required fix pack available at:
http://www.sas.com/techsup/download/hotfix/itcm23.html
Operating System and Release Information
| SAS System | SAS IT Charge Management | Microsoft Windows NT Workstation | 2.3 | 2.3 | 8.2 TS2M0 | 8.2 TS2M0 |
| Microsoft Windows 95/98 | 2.3 | 2.3 | 8.2 TS2M0 | 8.2 TS2M0 |
| Microsoft Windows 2000 Server | 2.3 | 2.3 | 8.2 TS2M0 | 8.2 TS2M0 |
| Microsoft Windows 2000 Advanced Server | 2.3 | 2.3 | 8.2 TS2M0 | 8.2 TS2M0 |
| Microsoft Windows 2000 Datacenter Server | 2.3 | 2.3 | 8.2 TS2M0 | 8.2 TS2M0 |
| Microsoft Windows 2000 Professional | 2.3 | 2.3 | 8.2 TS2M0 | 8.2 TS2M0 |
*
For software releases that are not yet generally available, the Fixed
Release is the software release in which the problem is planned to be
fixed.
| Type: | Problem Note |
| Priority: | medium |
| Date Modified: | 2002-04-12 10:59:41 |
| Date Created: | 2002-02-15 11:25:21 |