SUPPORT / SAMPLES & SAS NOTES
 

Support

Problem Note 53845: The error, "invalid byte sequence for encoding 'UTF8'" occurs when you run the solnsvc_1400_load_groups job

DetailsAboutRate It

The SAS® Financial Management job, solnsvc_1400_load_groups, might fail with the following error:

ERROR: invalid byte sequence for encoding “UTF8”.

This error is most likely to occur if a group description in SAS® Management Console exceeds 100 characters and the job is running in a Linux operating environment.

In a Windows operating environment, the job runs successfully, but the group description is truncated.

The only workaround at this time is to limit the group description to 100 characters in SAS Management Console.



Operating System and Release Information

Product FamilyProductSystemProduct ReleaseSAS Release
ReportedFixed*ReportedFixed*
SAS SystemSAS Financial ManagementLinux for x645.4_M15.59.4 TS1M19.4 TS1M1
* For software releases that are not yet generally available, the Fixed Release is the software release in which the problem is planned to be fixed.