Problem Note 17973: Errors might occur creating graphs using Russian SAS® Enterprise Guide®
4.1
When using Russian SAS Enterprise Guide 4.1 to create graphs, errors
similar to the following might occur:
--------------------------------------------------------
System.ArgumentOutOfRangeException
A value between 'A' and 'Z' or 'a' and 'z' (inclusive) is expected.
Parameter name: AtoZ
Actual value was Ж.
[SAS.EG.ProjectElements]
A value between 'A' and 'Z' or 'a' and 'z' (inclusive) is expected.
Parameter name: AtoZ
Actual value was Ж.
----------------------------------------------------
at SAS.EG.ProjectElements.EGTask.Show(IWin32Window Owner)
at SAS.EG.SEGuide.MainForm.AddTask(Guid taskGuid, Element inputData,
Boolean bIsWizard)
at SAS.EG.SEGuide.MainForm.LaunchTask(Element target, Guid taskGuid,
Boolean bIsWizard)
at SAS.EG.SEGuide.MainForm.Task_Click(Object sender, EventArgs e)
atSyncfusion.Windows.Forms.Tools.XPMenus.BarItem.OnItemClicked
(EventArgsargs)
at Syncfusion.Windows.Forms.Tools.XPMenus.BarItem.PerformClick()
at Syncfusion.Windows.Forms.Tools.XPMenus.MenuGrid.NotifyItem
(BarItemitem)
at Syncfusion.Windows.Forms.Tools.XPMenus.MenuGrid.HidePopup
(PopupCloseTypepopupCloseType)
at Syncfusion.Windows.Forms.Tools.XPMenus.MenuGrid.ProcessItemClick
(BarItemitem)
at Syncfusion.Windows.Forms.Tools.XPMenus.MenuGrid.OnMouseUp
(MouseEventArgse)
at System.Windows.Forms.Control.WmMouseUp(Message& m, MouseButtons
button,Int32 clicks)
at System.Windows.Forms.Control.WndProc(Message& m)
at Syncfusion.Windows.Forms.ScrollControl.WmMouseUp(Message& msg)
at Syncfusion.Windows.Forms.ScrollControl.WndProc(Message& msg)
at Syncfusion.Windows.Forms.Grid.GridControlBase.WndProc(Message&
msg)
at Syncfusion.Windows.Forms.Tools.XPMenus.MenuGrid.WndProc(Message&
m)
at System.Windows.Forms.ControlNativeWindow.OnMessage(Message& m)
at System.Windows.Forms.ControlNativeWindow.WndProc(Message& m)
at System.Windows.Forms.NativeWindow.Callback(IntPtr hWnd, Int32 msg,
IntPtr wparam, IntPtr lparam)System.ArgumentOutOfRangeException
A value between 'A' and 'Z' or 'a' and 'z' (inclusive) is expected.
Parameter name: AtoZ
Actual value was Ж.
Select the Hot Fix tab in this note to access the hot fix for this issue.
Operating System and Release Information
| SAS System | SAS Enterprise Guide | Microsoft Windows XP Professional | 4.1 | 4.2 | 9.1 TS1M3 SP1 | 9.2 TS1M0 |
| Microsoft Windows NT Workstation | 4.1 | 4.2 | 9.1 TS1M3 SP1 | |
| Microsoft Windows 2000 Professional | 4.1 | 4.2 | 9.1 TS1M3 SP1 | 9.2 TS1M0 |
*
For software releases that are not yet generally available, the Fixed
Release is the software release in which the problem is planned to be
fixed.
| Type: | Problem Note |
| Priority: | high |
| Date Modified: | 2006-11-01 16:56:12 |
| Date Created: | 2006-06-30 07:33:57 |