A Basic EMP Study
/****************************************************************/
/* S A S S A M P L E L I B R A R Y */
/* */
/* NAME: MSAEX2 */
/* TITLE: A Basic EMP Study */
/* PRODUCT: QC */
/* SYSTEM: ALL */
/* KEYS: Basic EMP */
/* PROCS: SHEWHART */
/* DATA: */
/* */
/* SUPPORT: saswgr */
/* REF: Measurement Systems Analysis, Example 2 */
/* */
/****************************************************************/
data WaferMeasurements;
input Operator $ Trial Sample Value;
datalines;
A 1 1 70.52
A 1 2 74.40
A 1 3 73.54
A 1 4 75.20
A 1 5 73.99
A 1 6 71.89
A 2 1 71.03
A 2 2 76.24
A 2 3 74.68
A 2 4 74.33
A 2 5 75.39
A 2 6 74.70
B 1 1 72.08
B 1 2 77.78
B 1 3 76.93
B 1 4 78.40
B 1 5 76.04
B 1 6 75.98
B 2 1 72.89
B 2 2 78.90
B 2 3 78.93
B 2 4 76.90
B 2 5 75.01
B 2 6 72.87
C 1 1 70.56
C 1 2 76.88
C 1 3 75.34
C 1 4 75.65
C 1 5 73.91
C 1 6 73.73
C 2 1 68.61
C 2 2 78.61
C 2 3 76.35
C 2 4 75.02
C 2 5 75.46
C 2 6 71.55
;
%basicemp(WaferMeasurements, condition=Operator);