Table 15.2 shows the parameters that are used in this example.
Table 15.2: Parameters
Parameter Name |
Interpretation |
---|---|
length[period] |
Length per period (in hours) |
demand[period] |
Demand per period (in megawatts) |
num_avail[type] |
Number of units available per generator |
min_level[type] |
Minimum level (in megawatts) per generator |
max_level[type] |
Maximum level (in megawatts) per generator |
unit_cost[type] |
Hourly cost (in pounds) of running each generator at minimum level |
excess_cost[type] |
Extra hourly cost (in pounds) per megawatt at which a unit is operated above minimum level |
startup_cost[type] |
Cost (in pounds) of starting up each generator |
reserve |