When you create a gallery in Gallery
Manager, you use primary and secondary filters to subset the reports
that are on the SAS Content Server. By default, primary filters must
reduce the number of reports to no more than 4,000 before you can
continue with the next step to subset the reports further with secondary filters.
Secondary filters must reduce the number of reports to no more than
2,000 before you can finish creating the gallery.
The default limits are
specified to help manage the size of galleries and avoid unnecessarily
large report sets that make it difficult to locate specific reports.
However, you can specify the default limits to meet the needs of your
organization if you need larger or smaller galleries.
To specify your own
default limits, perform the following steps:
-
Open SAS Management
Console with administrator login credentials.
-
On the
Plug-ins tab, expand
Application ManagementConfiguration Manager.
Note: The Configuration Manager
is installed as part of the SAS Web Infrastructure Client. If you
do not see this plug-in in SAS Management Console, then you can install
it in the
Software Deployment Wizard by selecting
Install Additional Software and selecting the SAS Web
Infrastructure Client.
-
Right-click
ITRM Gallery Manager 3.2 and select
Properties.
-
On the
Advanced tab, specify the following parameters:
-
itrmgm.PrimaryRptCnt specifies the limit for primary filters.
-
itrmgm.SecondaryRptCnt specifies the limit for secondary filters.