Using the Object Manager |
Using CreateObjectByServer to Make a Connection |
Samples 1 through 5 show how to create a connection by specifying server parameters (machine, protocol, port) directly in the source code.
Samples 1, 2, and 3 show synchronous connections. The synchronous connection is the most frequently used and is the simplest connection to create.
Samples 4 and 5 use asynchronous connections. The advantage of making an asynchronous connection is that the client application can continue to execute code while the connection is being established. An application that interacts with multiple SAS servers might create asynchronous connections to all of the servers at the same time.
When making asynchronous connections, the ObjectKeeper maintains a reference to the created object until you call ObjectKeeper.RemoveObject. This call is not shown in the code for samples 4 and 5.
The object factory adds the newly created object to the ObjectKeeper as soon as the connection is established. You can then use the ObjectKeeper to get the connection.
Dim obObjectFactory As New SASObjectManager.ObjectFactoryMulti2 Dim obSAS As SAS.Workspace Set obSAS = obObjectFactory.CreateObjectByServer( "myName", True, Nothing, "", "")
Dim obObjectFactory As New SASObjectManager.ObjectFactoryMulti2 Dim obSAS As SAS.Workspace Dim obServer As New SASObjectManager.ServerDef obServer.MachineDNSName = "RemoteMachine.company.com" Set obSAS = obObjectFactory.CreateObjectByServer( "myName", True, obServer, "", "")
Dim obObjectFactory As New SASObjectManager.ObjectFactoryMulti2 Dim obSAS As SAS.Workspace Dim obServer As New SASObjectManager.ServerDef obServer.MachineDNSName = "RemoteMachine.company.com" obServer.Protocol = ProtocolBridge obServer.Port = 6903 Set obSAS = obObjectFactory.CreateObjectByServer("myName", True, obServer, "myUserName", "myPassword")
Dim obObjectFactory As New SASObjectManager.ObjectFactoryMulti2 Dim obObjectKeeper As New SASObjectManager.ObjectKeeper Dim obSAS As SAS.Workspace Dim obSAS2 As SAS.Workspace Dim obServer As New SASObjectManager.ServerDef Dim obServer2 As New SASObjectManager.ServerDef obServer.MachineDNSName = "MachineA.company.com" obServer.Protocol = ProtocolBridge obServer.Port = 6903 obObjectFactory.CreateObjectByServer "myName", False, obServer, "myUsername", "myPassword" obServer2.MachineDNSName = "MachineB.company.com" obServer2.Protocol = ProtocolBridge obServer2.Port = 6903 obObjectFactory.CreateObjectByServer "myName2", False, obServer2, "myUsername", "myPassword" ' Note that the first parameter here matches the first parameter in the ' call to CreateObjectByServer Set obSAS = obObjectKeeper.WaitForObject("myName", 10000) Set obSAS2 = obObjectKeeper.WaitForObject("myName2", 10000)
Public WithEvents obObjectKeeperEvents As SASObjectManager.ObjectKeeper Private Sub Form_Load() Dim obObjectFactory As New SASObjectManager.ObjectFactoryMulti2 Dim obObjectKeeper As New SASObjectManager.ObjectKeeper Dim obSAS As SAS.Workspace Dim obSAS2 As SAS.Workspace Dim obServer As New SASObjectManager.ServerDef Dim obServer2 As New SASObjectManager.ServerDef Set obObjectKeeperEvents = obObjectKeeper obServer.MachineDNSName = "MachineA.company.com" obServer.Protocol = ProtocolBridge obServer.Port = 6903 obObjectFactory.CreateObjectByServer "myName", False, obServer, "myUsername", "myPassword" obServer2.MachineDNSName = "Machineb.company.com" obServer2.Protocol = ProtocolBridge obServer2.Port = 6903 obObjectFactory.CreateObjectByServer "myName2", False, obServer2, "myUsername", "myPassword" End Sub Private Sub obObjectKeeperEvents_ErrorAdded(ByVal objectName As String, ByVal errInfo As String) Debug.Print "Error creating " & objectName & ": " & errInfo End Sub Private Sub obObjectKeeperEvents_ObjectAdded(ByVal objectName As String, ByVal objectUUID As String) Debug.Print "Added object " & objectName & ": " & objectUUID Dim obSAS As SAS.Workspace Set obSAS = obObjectKeeperEvents.GetObjectByUUID(objectUUID) Debug.Print obSAS.UniqueIdentifier End Sub
Using CreateObjectByLogicalName to Make a Connection |
The CreateObjectByLogicalName method creates a SAS object from a logical name definition. When you use CreateObjectByLogicalName, you must define server metadata for your connections and associate a logical name with the connection. This technique enables you to administratively change the machines where SAS is running without modifying your source code.
The following sample shows how to make a connection to a logical server.
Dim obObjectFactory As New SASObjectManager.ObjectFactoryMulti2 Dim obSAS As SAS.Workspace ' This assumes that your metadata configuration files are in the default ' location, or that the location of your configuration files is stored ' in the registry. If this is not the case, or you want each application ' on a given machine to use its own metadata repository, then you should ' call ' obObjectFactory.SetMetadataFile systemFile, userFile, false Set obSAS = obObjectFactory.CreateObjectByLogicalName("myName", True, "LogicalName", "LoginReference")
![]() |
![]() |
Copyright © 2010 by SAS Institute Inc., Cary, NC, USA. All rights reserved.