Previous Page | Next Page

Host-System Subgroup Error Messages

Messages from the Internal CALL Command Processor

The internal CALL command processor implements the TSO CALL command for use by an unauthorized caller outside of the Terminal Monitor Program.

SAST201I COMMAND SYSTEM ERROR +

Entering a question mark in the line following this message produces one of these additional messages:

  • NOT ENOUGH MAIN STORAGE TO EXECUTE COMMAND

  • IKJPARS RETURN CODE rc

Either the CALL command was unable to allocate enough memory to begin processing, or the system failed while it was parsing the command line. This message should not normally occur; inform your on-site SAS support personnel.

SAST202I TEMPNAME ASSUMED AS MEMBER NAME

You have not specified a member name with a CALL command invocation, and the CALL command processor used the member name TEMPNAME.

SAST203I PARM FIELD TRUNCATED TO 100 CHARACTERS

The parameter string that was passed to the program by the CALL command processor was too long and was truncated to 100 characters.

SAST204I DATA SET dsn NOT IN CATALOG

The CALL command processor was unable to locate the specified program data set. This message usually indicates that a data set name was misspelled. You will be prompted to enter the correct data set name.

SAST204I DATA SET NOT ALLOCATED, IKJDAIR RETURN CODE rc DARC drc CTRC crc

An error occurred while the data set was being allocated; inform your on-site SAS support personnel.

SAST205I MEMBERmem SPECIFIED BUT dsn NOT A PARTITIONED DATA SET

You have specified a program library in the CALL command that is not a valid load-module library. This message usually indicates that a data set name was misspelled.

SAST206I DATA SETdsn NOT USABLE +

Entering a question mark in the line following this message produces this additional information:

CANNOT OPEN DATA SET

The CALL command processor was unable to open the program library. This message usually indicates an invalid load-module library or a misspelled data set name.

SAST207I MEMBER mem NOT IN DATA SET

The CALL command processor could not locate the member name that you specified in the CALL command. This message usually indicates that a member name was misspelled. You will be prompted to enter the correct member name.

SAST207I BLDL I/O ERROR

An error occurred while searching for the program on the data set; inform your on-site SAS support personnel.

SAST208I COMMAND SYSTEM ERROR +

Entering a question mark in the line following this message produces one of these additional messages:

  • NOT ENOUGH MAIN STORAGE TO EXECUTE COMMAND

  • ATTACH RETURN CODE rc

Either the system was unable to allocate enough memory to invoke the specified program, or an error occurred while it was attaching the program. This message should not normally occur; inform your on-site SAS support personnel.

SAST209I INVALID PARAMETER LIST PASSED TO IKJDAIR

The CALL command processor passed an invalid parameter list to the TSO service routine IKJDAIR. This message should not normally occur; inform your on-site SAS support personnel.

Previous Page | Next Page | Top of Page