An engineer is interested in following up the IC Fabrication Screening experiment in Chapter 5 with a response surface design in order to identify factor settings that optimize the process. This experiment showed that acid flow rate was not significant, so that factor will not be considered here.
Table 7.1 describes the factors and responses of the new experiment with their ranges.
Table 7.1: Factors and Responses of the IC Fabrication Screening ExperimentType | Name | Low | High | Description |
Factors | TEMP | 1210 | 1220 | Deposition |
temp (C) | ||||
FLOW | 55 | 60 | Arsenic flow rate | |
TIME | 10 | 16 | Deposition time | |
ETCH | 1180 | 1200 | Etch rate | |
Responses | THCKNESS | Thickness of film | ||
RESTIVTY | Resistivity of final | |||
film layer |
The goal of the experiment is to determine factor settings that result in a film thickness of 60 and maximum resistivity.